Meridyan engineering
What we’ve tested.
What we’re building.
Explore the clasp’s battery, water-resistance target and component design, and see what independent testing found about heart readings at the underside of the wrist.
Battery life & water resistance
10+ days per charge in power modelling
Meridyan is designed around a custom 88 mAh battery and charges with a magnetic connector. We’ll publish measured battery life after testing finished units.
IP67 design target
We’re designing Meridyan for everyday exposure such as sweat and rain. We’ll confirm whether it can be worn in the shower after testing. Take it off before swimming.
Inside the clasp
Hardware designed around the wrist.
A custom folding circuit board and an 88 mAh battery fit the space inside the clasp. The complete digital design is smaller than a Rolex Submariner clasp. Wear testing will tell us how it feels across different wrists and bracelet fits.
- Optical heart sensing
- Texas Instruments optical sensing chip, with multi-wavelength LEDs and twin light sensors from ams OSRAM.
- Skin temperature
- Melexis infrared temperature sensor.
- Motion
- STMicroelectronics accelerometer and gyroscope.
- Bluetooth and processing
- Nordic Semiconductor Bluetooth chip.
- Power
- Nordic power management, a custom 88 mAh battery and a magnetic charging connector.
- On-device storage
- Renesas flash memory, designed to keep recording when your phone isn’t nearby.
Wrist-position feasibility study
Can a clasp get a clear heart signal?
Before designing Meridyan, we asked CSEM, a Swiss research institute, to find out whether the underside of the wrist, where the clasp sits, could give reliable heart readings. Ten people wore a general-purpose research sensor while sitting, typing, using a phone, driving and walking. The institute compared it with a chest-strap heart monitor.
- 2.5 bpm at rest
- The reported heart-rate difference was within 2.5 beats per minute at rest and within 5 while walking.
- 9.7 milliseconds
- Average difference in the time between beats compared with the chest strap. At 60 beats per minute, that’s less than 1% of the one-second gap between beats.
- 89% usable
- The underside of the wrist provided usable heart-rate variability readings 89% of the time, against the institute’s 50% target.
Heart-rate variability measures how the gap between beats changes over time. It’s one of the signals Meridyan uses for stress and recovery trends. The institute’s beat-timing target was 20 milliseconds, and its testing covered everyday movement as well as time spent sitting.
What comes next
The study used a general-purpose sensor to test the clasp position. Meridyan’s patent-pending sensor layout is designed specifically for the underside of the wrist, and we license the sensing algorithms from the same institute. We’re aiming to improve on the feasibility results. We’ll test the finished clasp on a wider range of people, including overnight, and publish those results before shipping.
Developed with Haltian
Engineering experience from Oura’s first two rings.
Haltian was a design and engineering partner on Oura’s first and second generation rings. We worked with Haltian on Meridyan’s digital engineering, including electronics, charging, battery architecture, mechanics and assembly.
Read Haltian’s Oura case study